Product category codes are indicated below. Click the link above, each design number below represents a James Hardie 1 hour Fire Resistive Wall Assembly. Each design also specifies the test standard(s) used and performance ratings achieved so code compliance can be determined. Windstorm Rated Exterior Swinging Doors (ZHCW) This category covers exterior swinging doors intended for use as components in swinging door type windstorm-rated assemblies (not window assemblies, skylights, louvers or shutters). UL certified special locking arrangements include the UL symbol, LISTED or CERTIFIED, SECURITY, and Special Locking Arrangement. Refining search results with filters makes it easy to also identify alternate solutions. Finishes that contribute to the total fire resistance rating of a wall must meet certain minimum installation requirements. Glazing Glazing used in fire doors, transoms, sidelights and fire windows is regulated in the opening protectives portion of the code, and may be limited in aggregate and individual sizes and dimensions. Therefore, twoseparate tables are required. UL Product iQ combines UL Safety Certification information trusted around the globe with the intuitive design and functionality of a modern search engine. These fire door assemblies should be certified in accordance with UL 10A, 10B, and 10C as applicable, and installed in accordance with NFPA 80. When the Listing Mark of UL is stamped into the frame, one of the following abbreviated product identities may be used: FDF in lieu of Fire Door Frame A temperature-rise rating of 250F, 450F or 650F reflects the limiting potential temperature rise on the unexposed surface of the door during the first 30 minutes of fire exposure. fire protection rated products. These frames are intended for installation in conjunction with fire doors, hardware, glazing and/or other accessories that together form a fire door assembly or a fire window assembly, which provides the degree of fire protection to the opening. The fire resistance rating is determined in accordance with Table 1 utilizing the appropriate aggregate type used in the masonry unit and the equivalent thickness. Standard Methods for Sampling and Testing Concrete Masonry Units, ASTM C140/C140M-18. See TEK 17-01D(ref. Min. Information concerning the specific air-leakage rating, mounting locations, installation clearances, and the like is provided in the detailed installation instructions accompanying each leakage-labeled product. reference current ul joint systems directory for all general information, material designations, thickness and fire ratings. Code requirements for exit doors include specific criteria that are not applicable for doors that are not in the means of egress travel path. 20-minute rated frames 20-minute type door frames may be provided with sidelights and/or transom lights as indicated in the individual certifications. Assemblies incorporating fire-resistance rated glazing comply with all of the requirements that a fire-resistance rated wall must meet (e.g. FDF-P in lieu of Fire Door Frame with Panels These doors are tested to verify that the release mechanism is constructed so that a horizontal force of 50 pounds or less will open the emergency panel. The following steps provide a systematic approach that can be followed to provide a safe, code compliant installation. Some manufacturers have opted to mark their frames for conformity to positive pressure as noted below. fire resistant assemblies wall penetration details usg j2133 rev 0 issued 10/16/2015. NA. Table 7 applies to finishes on the non-fire-exposed side of the wall, and Table 8 applies to finishes on the fire-exposed side. Leakage ratings for door assemblies are determined at ambient air temperature (75F) and/or elevated air temperature (400F) and at three air pressure differentials including 0.10, 0.20, and 0.30 in. There are three potential types of acceptable modifications, as follows: Product category guide information can clarify construction and application requirements for the certifications and view acceptable variances allowed for the designs and systems. This category consists of a diverse range of door types including swinging, sliding, coiling and curtain type products manufactured from aluminum, steel, wood and woven fabrics. Whether you need preformed plugs or the flexibility of an expanding foam, sealant or moldable putty, 3M has you covered. Leakage-rated door assemblies may be assembled at the job site, or may be factory assembled. Connect with us in person or online, around the globe. This link provides information on construction details, including clarifications and permitted variations. FDF-L in lieu of Fire Door Frame for Lights Then, review the appropriate windstorm rated assembly certification to determine if it complies with all mandated test criteria. ASTM International, Inc., 2016. Westbrook Block is a proud producer of Underwriters Laboratories (UL) Approved Fire-Rated CMU, both Light Weight and Normal Weight densities, in 2-, 3- and 4-hour configurations. The manufacturer chooses whether an artificial bottom seal is applied or not during the test. Special Locking Arrangements (FWAX) This category covers assemblies intended to be mounted on door frames of outward-swinging exit doors for the purpose of locking such doors against unauthorized egress. National Gypsum pioneered the development of fire-rated horizontal membranes with UL design G586 . The performance of door frames for exterior swinging doors as a component of an assembly is based upon test methods in SDI-BHMA A250.13. Products bearing any of these UL marks comply with the definition of a listed product in the code, and should be considered to be listed. Among other criteria UL 305 requires the actuating bar to extend across not less than one half of the width of the door leaf. These assemblies consist of combinations of individual component products, which may include the door, frame, hardware, gasketing and other door accessories. UL classified, 1 hour fire rated cover for recessed 2'x4' luminaires, troffers, and fluorescent fixtures. Panel or tile size (in.) This article describes two sources of information that can . Explore our press releases and news updates. The result, Tef, is then added to the concrete masonry wall equivalent thickness, Te, and used in Table 1 to determine the walls fire resistance rating (i.e., the equivalent thickness of concrete masonry assemblies, Tea = Te + Tef). Gasketing and edge seal materials There is often confusion about whether UL certified gasketing and edge seal materials are required for fire doors used in smoke barriers and smoke partitions. Use: Rated ceilings above corridors, mechanical rooms, or other incidental uses required by Section 509 of the IBC. Installation instructions are not required to be shipped with frames that are to be installed in accordance with NFPA 80 and SDI A250.11. Fire-rated wall, floor and ceiling assemblies provide the necessary fire and smoke barriers to create compartmentalization during a fire, safeguarding against the spread of fire and smoke within a building or to and from a building. The finish material must also be continuous over the entire wall. containing fires within various fire areas). UL Design Studio, Architectural Assemblies & Estimators | USG Windstorm rated products in the following categories include Certified products that have been investigated for use in the windstorm rated assemblies described above. Classified glazing material is usually provided by someone other than the window frame manufacturer and installed after installation of the window frame in the building. Supplementary information about Fire and Sound Rated Assemblies including UL Types. It includes the flexibility to search by product name, master format number, related installation code section, keywords and other terms. Confirm if doors and windows are required to limit the passage of fire or smoke The fire safety system embodied in building code requirements is based on the use of walls, barriers and partitions designed to contain fires and the resulting smoke in certain areas within the building. USG provides resources here for our UL wall assemblies for seamless integration into any construction project. Assembly rating:2 Hour; Gypsum wall to bottom of fire-proofed steel I-beam to concrete over metal deck (Max. This could include descriptions such as Fire Door Frame, Transom or Sidelight Panel, Fire Window Frame (3/4 Hr., 1 Hr. Leakage-rated door assemblies are intended for installation in accordance with NFPA 105 and the installation instructions provided with each leakage-rated component. Use the link below instead. It is a key differentiator for products within the exterior wall assembly market. Oversized doors Freight elevator type, rolling steel type, and sliding or swinging steel-covered composite type, hollow-metal type, metal-clad (Kalamein) type, sheet-metal type and tin-clad type are fire tested up to the sizes recorded in the listings published under their respective product categories. Type C gypsum board will maintain its material integrity in a fire condition better than Type X gypsum board. NOTE: If sound testing is associated with the search, it will be displayed with the results. In normal use these doors open upon the approach of a person or are provided with power-assisted manual operation. It is a 2-hour wall and is fire-rated on both sides. Locations Building and life safety codes require doors to be provided in specific locations to protect the door openings. Other categories for Windstorm Rated Products Product categories have been established to cover other products that have been investigated for use in windstorm rated assemblies, including: Installation considerations To determine if a particular windstorm rated assembly is suitable for use in a specific application, first identify all test standards or protocols and performance ratings specified by the codes or regulations being enforced. Typical equivalent thickness values for these units are listed in Table 2. Our certification services, which provide evidence that products and systems meet regulatory and market requirements, include: Our environmental sustainability validation services, which provide evidence to architects and designers that products meet environmental requirements, include: Our testing services assess compliance to UL Solutions and industry standards, including: Our advisory services help ensure building owners that exterior wall assemblies will perform as expected and include: We understand that meeting fire resistance safety requirements can be challenging, which is why we provide training, advisory, testing, Verification, inspection and certification solutions for the fire resistance industry. Unless otherwise indicated in the individual Certifications, these materials have not been investigated by UL to determine compliance with safety glazing requirements. This guideline stipulates that when applying the fire resistance calculation procedure of ACI/TMS 216.1 to products manufactured using aggregate types that are not listed in ACI/TMS 216.1, at least two full-scale ASTM E119 tests must be conducted on assemblies containing the unconventional material. Model codes include specific requirements for exit door hardware which includes the hardware mounting height, locks and latches, special locking arrangements, and delayed egress locks, and other locking arrangements. 2. Frame manufacturers may mark the frame with the letter S but this is not required by UL or by model codes. These listings are short summaries to serve as a . All of these assemblies are required to have a fire-resistance rating. S rated door assemblies Model codes often require fire doors installed in corridors and smoke barriers to meet the requirements for a smoke and draft control door assembly when tested in accordance with UL 1784. You are leaving the UL Solutions website for an external site. Private commercial listing services allow the designer to select a fire rated assembly that has been previously tested, classified and listed in a published directory of fire rated assemblies. Latch retraction options are only permitted if they are electrically operated and can be connected to an initiating device or fire alarm control panel. Access UL certification data on products, components and systems, identify alternatives and view guide information with Product iQ. . Welcome to the cutting edge of safety science. FDF-20 in lieu of Fire Door Frame Fire Rating 20 Minutes Fire Rated Wall Assemblies. UL design G586 can span 8'-0" from wall . The FF130-2X4 luminaire covers are UL fire rated enclosures designed to protect recessed 2' by 4' luminaires, troffers and fluorescent fixtures. The UL Mark on a product means UL has tested and/or evaluated representative samples of that product and determined that they meet the requirements in the applicable standard(s). Fire exit hardware is investigated in accordance with UL 305 and UL 10C. Standard Specification for Concrete Aggregates, ASTM C33/C33M-18. D798 Unres NWC MK6GF. Firestop: Installed in fire-rated construction. UL Solutions structures this activity to be distinct and separate from its conformity assessment bodies. Door frames may be provided with mullions, transom panels, or transom lights. The system also is somewhat inflexible in that little variation from the original tested wall assembly is allowed, including unit size, shape, mix design, constituent materials, and even the plant of manufacture. Panic Hardware (FVSR) This category covers devices intended for mounting on or integral with outward-swinging doors to facilitate the safe egress of persons in case of emergency. These fire window assemblies should be certified in accordance with UL 9, and installed in accordance with NFPA 80. Concrete masonry is widely specified for fire walls and fire barriers because concrete masonry is noncombustible, provides durable fire resistance, and is economical to construct. These devices are intended for use in applications where codes regulate special locking arrangements, delayed egress unlocking, access-controlled egress, and electromagnetically locked exit (egress) doors. 1), which outlines a procedure to calculate the fire resistance ratings of concrete masonry assemblies. The lower roof assembly within 4 feet (1220 mm) of the wall has not less than a 1-hour fire-resistance rating and the entire length and span of supporting elements for the rated roof assembly has a fire-resistance rating of not less than 1 hour. difference between fire resistance ratings for masonry assemblies obtained through IBC versus a listing service such as UL or FM?, FAQ 21-14, National Concrete Masonry Association, 2014. Helpful instructions and resources to help you locate UL fire rated assemblies, designs and systems. . Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies, ACI/TMS 216.1-14. Putting it all together In order to provide the desired door installation that complies with applicable code requirements it is important to identify the wall construction, determine the type of door required, evaluate means of egress considerations, understand the requirements applicable to glazing, and select the appropriate hardware. All rights reserved. water column. They are also required to swing in the direction of egress travel where they serve a room or area containing 50 or more persons or certain occupancy types. Fire door assemblies typically have an hourly fire- protection rating that is nominally less than the corresponding hourly fire-resistance rating of the vertical (wall) assembly in which they are installed. Selecting the right UL Fire-Rated Assembly: Establish the hourly rating needed to meet code requirements. Anyone directly involved with a product including manufacturers, owners, contractors, and regulatory authorities can request a Field Evaluation. Product Guide information is available in the UL Product iQ database. Fire window assemblies typically have an hourly fire-protection rating somewhat less than the corresponding hourly fire-resistance rating of the vertical (wall) assembly in which they are installed. 1. The calculated fire resistance method is based on extensive research and testing of concrete masonry walls. alternative means approved by the building official per Section 104.11 of the IBC. Gaskets and edge seals are categorized as previously discussed in the Positive Pressure Fire Doors section. Devices so Classified are covered under Hardware (GWGR). Products for use in Windstorm Rated Assemblies (ZHLL) This category covers products intended for use in windstorm-rated assemblies (ZHLA). UL FIRE RESISTIVE ASSEMBLIES Fire Ratings specied in this section pertain to UL Classications which are based on standard test method ANSI/UL263, ASTM E11 9, UBC 7-1, NFPA 251, CAN/ULC - S101M . Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. Fire door and window hardware and accessories are certified under a variety of product categories. We'll send you a link that lets you create a new password. We use cookies to provide a personalized site experience. Explore our business intelligence-building digital tools and databases, search for help, review our business information, or share your concerns and questions. The artificial seal may be any material, such as an impermeable plastic sheet or tape. Welcome to the cutting edge of safety science. C. IDENTIFICATION OF UL CERTIFIED PRODUCTS This is accomplished by ensuring that the temperature of the tensile reinforcement does not exceed 1,100 F (593 C) during the rating period. thick. UL certified fire exit hardware includes the UL symbol, LISTED or CERTIFIED, and Fire Exit Hardware. (ref. Determine the existing or planned building elements, including structural, mechanical, electrical, and finish materials, in the fire-rated assembly. The production of UL Certified products is periodically audited by UL Staff at the manufacturing facility to verify that the products continue to comply with the applicable requirements in the standard used to evaluate the products. A four or five-letter code following each product category in this guide is the UL category code number (CCN), which identifies product categories under which products are certified by UL for the identified application. A secure, online source for increased visibility into your UL Solutions project files, product information, documents, samples and services. Door frames bearing a UL Certification Mark without an hourly rating and provided with masonry wall anchors can be used in conjunction with fire doors rated up to 3 hours and installed in masonry walls having fire resistance ratings not less than the rating of the door. Fire door frame and fire window frame Marks include the UL symbol, the word LISTED or CERTIFIED and a description of the certified product. This information, if needed, should be available in the manufacturers installation instructions and may be indicated on the manufacturers OPBW Card available through the UL ProductIQ Tool. UL offers a field evaluation service that provides a method to assist you in making your decision whether to accept the product and/or approve the installation. These frames should be glazed with Classified Fire-protection Rated Glazing Materials (KCMZ). For example, the IBC and ACI/TMS 216.1 include provisions for ceramic fiber joint protection for precast panels, which are similar to concrete masonry walls in that both rely on concrete for fire protection, and both are governed by the ASTM E119 heat transmission criteria (see Figure 4). ASTM International, Inc., 2018. The Product Guide Information includes the scope of the products and assemblies covered, information relating to limitations or special conditions applying to the product, the requirements used for the investigation of the products, general installation and use information, and information on product markings and the UL Mark to be used on the product. The assembly consists of a frame, doors and necessary hardware. Step-by-step instructions on locating rated walls, floors, beams and columns. F. FIRE DOOR AND WINDOW HARDWARE AND ACCESSORIES. These frames and the labeled components are identified in the individual certifications. Step-by-step instructions on locating through penetration firestop system certifications. American Concrete Institute and The Masonry Society, 2014. International Building Code 2015. International Code Council, 2015. International Building Code 2018. International Code Council, 2018. 10). Certified products includes the UL symbol the word LISTED or CERTIFIED and Controlled Exit Panic Device. 11). Swinging fire doors, fire tested under positive pressure in accordance with UL 10C and bearing the Smoke and Draft Control Door S marking have been investigated in accordance with UL 1784 and were determined to have an air leakage rate of the door assembly not exceeding 3.0 cfm per square foot of door opening at 0.10 inch of water column? This also applies to partially grouted concrete masonry walls where all ungrouted cells are filled with an approved material. For example exit doors serving a hazardous occupancy or exit doors serving spaces with an occupant load of 50 in certain occupancy types are not allowed to be provided with a latch or lock, unless it is listed panic hardware or fire exit hardware. Were everywhere your business needs us to be. For finishes on the fire-exposed side of the wall, a time (from Table 8) is assigned to the finish.

Western Morning News Obituaries, Volkswagen Financial Services Uk, Articles U

About the author