If you want to use this amplifier, reset the function bit 2209#4 to 0. The control power supply voltage decreases. $2 2021-21 Lot of 27 Rookie Cards w/ Prestige, Playbook, STANLEY, P Sports Mem, Cards & Fan Shop Sports Trading Cards Trading Card Lots Even though the nth axis (axis 18) READY signal (MCON) went off, the servo amplifier READY signal (DRDY) is still on. Can be issue with the 3ph supply. PSMR: Input voltage is in the openphase condition. Some errors, depending on the machine and its series, identify the symptom of a problem, and others point straight to the cause. Regenerative discharge energy is too high. This error usually occurs as the result of an improperly set parameters. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); This site uses Akismet to reduce spam. 2024 (number of position feedback pulses per motor revolution). The interference check evade function of cutter compensation determines that an evade operation will lead to danger. Refer to diagnosis display No. Nestled at the base of Utah's Wasatch Mountains just a few miles from Salt Lake City, Murray City Power is a publicly owned, municipal electric utility created in 1913 when the community demanded affordableand more reliableelectricity, along with local control over a vital service. The temperature of the regenerative resistor has risen abnormally. The nth axis (axis 18) servo amplifier READY signal (DRDY) went off. Position control system fault. Contact a FANUC expert today. Refer to diagnosis display No. At a quick glance, JIS and Phillips appear to be the same, but a close look reveals that their design is slightly divergent. A06B-6120-HXXX The G code command block of the canned cycle does not specify the Z point of the drilling axis. The motor operation is continued under the warning. AL03: The Temperature of the main circuit heat sink has risen abnormally. A06B-6091-HXXX Alarm Code #3 The problem is for voltage of the fan must be same. 2) PSMR: The internal cooling fan failed. Relay contacts for the dynamic brake is faulty. A first to third reference position return cannot be executed because the reference position has not yet been established. Ready to start your automation journey? AL06: The Input Power Supply is abnormal (open phase). 2) A proper value (111 or 111) is not set in parameter No.2022 (motor revolution direction). The main circuit power module (IPM) has detected an abnormal condition. The parameter setting that determines the relationship between the rotation axis and rotation plane is incorrect. High Voltage Alpha Amplifier A06B-6097-H***. Do yourself a favor and make sure it is a Japanese Industrial Standard tipped screwdriver. The input power supply is abnormal (open phase) or the main circuit capacitor was not recharged within the specified time. 414 SERVO ALARM: nTH AXIS DETECTION RELATED ERROR. Your email address will not be published. Learn how your comment data is processed. The digital servo software detected the soft thermal state (OVC). Learning control (bit 5 of parameter No. Power. Temperature of the main circuit heat sink has risen abnormally, Copyright Tri Star CNC Services LLC. The input power supply of the main circuit has an imbalance. How to Diagnose a FANUC 414 Servo Alarm: Step 1 - Access the electronics cabinet with the power on (WARNING: Hazardous voltage inside). FANUC ALARM. The current control cycle settings (parameter No. Turn on the main breaker of the machine and leave the CNC off. Excessive speeddeviation NOTE How to check the speed feedback signalObserve the speed feedback signal with an osciloscopeafter turning on power and setting the rotation command off(motor stopped and drive power set off). Then high voltage on the DC bus due to the PSM or power to the PSM. PMC SYSTEM ALARM: 951. The nth axis (axis 14) overload signal is on. Refer to diagnostic display No. Have questions about a FANUC CNC product? In the interference check evade function of cutter compensation, a further interference occurs for an already created interference evade vector. Select your Fanuc Part to quickly jump to that section. SVM: The control power supply voltage has dropped. Consult the list below for a brief description of the code indicated on your CNC machine controls. If you want to use the HC alarm avoidance function, use an amplifier that supports it. Even though the nth axis (axis 18) READY signal (MCON) went off, the servo amplifier READY signal (DRDY) is still on. The input power supply is abnormal. ;2) A leadingedge offset of threedimensional cutter compensation is applied during sideface offsetting of threedimensional cutter compensation, or a sideface offset of threedimensional cutter compensation is applied during leadingedge offsetting of threedimensional cutter compensation. He was wondering what the different codes stood for, so we wanted to go ahead and list the different alarm codes for this series. 1) SVM: IPM (intelligent power module) detected an alarm. In torque control of PMC axis control, the parameterset allowable cumulative travel distance has been exceeded. To order a replacement part or a repair job, please call 800-691-8511 or email sales@mroelectric.com. Software disconnection alarm of the pulse coder. Use of highspeed HRV is specified for a controlled axis of an amplifier which does not support highspeed HRV. A high current is an abnormal current that can be caused by noise. Once the system has reached this point all the drives become NOT READY and the machine will not be able to move.The amplifier units tend to look alike so it's not a bad idea to access the electronics cabinet with power on (please do it safely) and look at the status displays of the units while the alarm is occurring. From early PMS modules to the latest aiPS; the alarms have been relatively consistent. "*2" marks the warnings. When bit 2 of parameter No. AL07: In the main circuit the DC Voltage at the DC link is abnormally high. When a P/S alarm occurs on the machine tool, full-time maintenance personnel must be present to deal with it. Fanuc Oi MF power supply alarm Hi Guy , My cnc milling machine have alarm as below , SYS_ALM129 ABNORMAL POWER SUPPLY (AMP 02 ) / LINE 1 FSSB RFOM SERVO CARD 2022/02/24 13:40:18 PROGRAM COUNTER : 101F8714H ACT TASSK : 01000000H ACCESS ADDRESS : - ACCESS DATA : - ACCESS OPERATION : - What action action should i do at next step ? The axes of the 2axis amplifier were assigned to the fast type interface. 415 SERVO ALARM: nTH AXIS EXCESS SHIFT. The input power supply is abnormal (open phase). 3) series SVU: The motor current is too high. Current exceeding the preset value has continued longer than normal. Results for {phrase} ({results_count} of {results_count_total}), Displaying {results_count} results of {results_count_total}, FANUC AC Serial Spindle A06B-6062, A06B-6063, A06B-6064 Alarms and Error Codes, FANUC Alpha Servo Amplifier Module Alarm and Error Codes, FANUC Alpha Power Supply Errors and Alarm Codes, FANUC Alpha I Spindle Amplifier Alarms and Error Codes, FANUC Beta Servo Amplifier Unit Alarms and Error Codes, FANUC Beta Servo A06B-6093-H15x / H17x series I/O Alarms and Error Codes, FANUC Beta I Servo Unit Alarms and Error Codes, FANUC Beta I A06B-6132 Series Servo Unit Alarms and Error Codes, FANUC Beta I Servo Power Module A06B-6134 and A06B-6164 Error Codes, FANUC DC Axis Unit Alarms for A06B-6047 Series, FANUC AC Axis Unit Alarms for A06B-6050 Series, FANUC Alpha Spindle Amplifier Module Alarm and Error Codes, FANUC AC Spindle S Series A06B-6059 Alarms and Error Codes, FANUC AC Spindle I Series A06B-6060 Alarms and Error Codes, FANUC AC Spindle Amplifier Alarms for A06B-6044, A06B-6052, A06B-6055 Series, FANUC AC Servo Amplifier Alarms for C Series A06B-6066. Nth axis (axis 18) digital servo system fault. A cooling fan for the control circuit has stopped. 1) A G41.3 or G40 block contains a move command. WHAT MEANS THIS ALARM??? The main circuit power module (IPM) has dedected an abnormal condition. AL05: The main circuit capacitor was not recharged within the specified time. Check that the servo interface module and servo amp are connected. In this example, there is a Fault with the fault code of SRVO-002 and a note saying Teach Pendant E-stop. If you know your FANUC PSM or aiPS power supply module is faulty either type the part number to the right, fill in our get a quote form or call us for more information. The digital servo software detected a broken wire in the pulse coder. The one tool you will definitely need is a screwdriver. b. FANUC Parts We Service: FANUC Alpha, Alpha i series & Alpha is series Step 4. 400 Alarms600 AlarmsBeta is 6130 AlarmsSVPMi (6134, 6230) Alarms. The battery voltage of the absolute pulse coder is low. 2023. Abnormal servo motor load has been detected. The main circuit capacitor was not charged with the specific time. The fan failure on the PSM is reported in two stages. FANUC service>>FANUC alarm codes>>Power supply module alarms. Alternatively, the regenerative discharge circuit is abnormal. a. 413 SERVO ALARM: nth AXIS LSI OVERFLOW. A cooling fan for the control circuit has stopped. 1) PSM: The spare discharge circuit of the DC link is abnormal. The generating station is located in Delta, Utah. SERVO ALARM: n AXIS SYNC TORQUE (M series). If your CNC displays a Fanuc alarm code, Tennessee Industrial Electronics, LLC can provide fast, reliable diagnosis and repair services. The parameter setting (No. Please refer to the following alarm codes pertain to the FANUC 200VAC and 400VAC PS modules with codes PSM HV, PSM, and PSM-R (part numbers started from A06B-6077, A06B-6081, A06B-6087, A06B-6091). ;If this alarm is issued, cancel the relevant mode, then specify a different mode. Abnormally high current in the Land Maxis motors, The regenerative discharge circuit may be faulty. Intermountain Power Project. The input power supply is abnormal (open phase). Itll get you up to speed with a solid CNC foundation fast. If your CNC machine tool is throwing an error you need to track down the source of the problemwhich isn't always as easy as it sounds. This error occurs as the result of improperly set CMR. Once this operation is performed, the alarm will not be issued at the next restart. The control power supply voltage decreases. A communication error for the serial pulse coder was detected. The temperature of the heat sink has risen. CNC Electronics West Inc an Independent GE Fanuc parts repair company; not affiliated too GE Fanuc, Fanuc, Siemens, Mazak or other entities. Input supply voltage imbalance, IGBT defective. . (5axis mode) This alarm is issued when;1) Threedimensional cutter compensation (sideface offset and leading edge offset) is applied during cutter compensation, or cutter compensation is applied during threedimensional cutter compensation (sideface offset and leadingedge offset). Why can I not find any connection information on A06B-6077-H002? The temperature of the regenerative resistor has arisen abnormally. We will perform the neededFANUC power supply repairs or recommend the purchase of a new FANUC power supply module. For more information or to get a quote on a FANUC power supply, please call 800-691-8511 or email sales@mroelectric.com. 1 (for PSM-5.5i to 15i) The main circuit power module detected an abnormal condition. AL04: In the main circuit the DC voltage (DC Link) has dropped. 4. We also have Cookbooks for Feeds and Speeds, G-Code Programming, CNC Manufacturing and Shop Management, DIY CNC, and dont forget the CNC Cookbook Blogwith over 4 million visitors a year its the most popular CNC blog by far on the web. The contents of the error register for the nth axis (axis 18) exceeded 231 power. 2023 (number of speed feedback pulses per motor revolution). The difference between the errors in the semiclosed loop and closed loop has become excessive during dual position feedback. 1) PSMR: The regenerative discharge amount is too large. FANUC Alpha Power Supply Errors and Alarm Codes Please refer to the following alarm codes pertain to the FANUC 200VAC and 400VAC PS modules with codes PSM HV, PSM, and PSM-R (part numbers started from A06B-6077, A06B-6081, A06B-6087, A06B-6091 ). ;2) At startup, the included angle of the tool direction vector and move direction vector is 0 or 180 degrees. We also provide repair services for FANUC Power Supplies. Check cable J91 between the Input Unit and Power Supply Unit, or for a failed Input Unit. If Alarm 59 presents on SPM in combination with AL.2 on PSM; then cooling Fan has stopped in the PSM. 1) The value set in Parameter No. Name (required) Company (required) Email (required) Comments / Questions? The input power supply of the main circuit has an imbalance. 200, 201, and No.204 for details. The position deviation value when the nth axis (axis 18) moves is larger than the set value. Alarms & Faults Power Supplies Joe Kaminski Joe Kaminski is an industrial automation specialist at MRO Electric. The input power supply is abnormal. Amplifier is ready (normal operating state). For further information please visit our dedicated Fanuc Alpha Power SupplyPage. When the system detects this, it will generally shut the machine down and generate a High-Current Alarm. Servo motor has overheated (estimated value). A cooling fan for the control circuit has stopped. The servo amplifiers tell the CNC they're not going to work either and the CNC displays an SV 606 alarm to pass the message to you. 200 and No.204 for details. The input power supply is abnormal (open phase). The power supply doesn't have direct communication with the CNC like the spindle and servo amplifiers do but the power supply (or PSM - power supply module) does talk to those units. A06B-6077-HXXX The main circuit capacitor was not recharged within the specified time. AL-05 Control power supply fuse blown FSSB communication was disconnected suddenly. can you help me? Internal cooling circuit failure, Overload, Input supply voltage imbalance, IPM failure, or control supply voltage decrease of the power module. 2084 and No. The main circuit power supply has an open phase. The position deviation value when the nth axis (axis 18) stops is larger than the set value. When the magnetic contactor is turned on, the phase sequence of the power supply cannot be determined. If Alarm 30 is present on the spindle amplifier module. I just replaced with after market, same specs, new fan it is working now. If DC voltage of main power supply is abnormally high, overvoltage alarms occurs (HV level: 430V DC). Internal cooling circuit failure, Overload, Input supply voltage imbalance, IPM failure, or control supply voltage decrease of the power module. ; To find out more about this fault Select MENU and arrow down to 4 ALARM and hit ENTER. Or, when the power was turned on, DRDY went on even though MCON was off. Don't attempt to perform anything discussed in this presentation if you are not both fully qualified to do so and have the equipment owner's permission to do so.Once you are done troubleshooting and before performing any maintenance, follow all plant safety and lockout procedures. 1023), odd number and even number, highspeed HRV control can be performed for one axis and not for the other. Refer to diagnosis display No. The spindle amplifier also sends word that it's taking a break by displaying an SP9113 alarm. Over current flowed into the input of the main circuit. E The input power supply is abnormal (open phase). We measured about 4.8ish volts. Try again from the manual reference position return. AL07: In the main circuit the DC Voltage at the DC link is abnormally high. Or, when the power was turned on, DRDY went on even though MCON was off. Do not confuse these alarms with Fanuc CNC control system power supply unit alarms; which are a different matter altogether. 2078 and 2079. ;2) The time required for deceleration to a speed of 0 exceeds the maximum value. Is Manual Machining Faster than CNC for Simple Parts? Hello, For further information please visit our dedicated Fanuc Alpha I Power Supply Module Page. A06B-6140-HXXX Servo drive alarms notes) The alarms marked by *1 have no solution unless control power supply is turned OFF and ON. In the main circuit the DC voltage (DC link) has dropped. Because of an FSSB communication error, a slave could not receive correct data. In the main circuit the DC voltage at the DC link is abnormally high. 2004, bit 0 of parameter No. 200, 201 for details. We are diligently working on your request and will respond shortly. DC voltage of the main circuit power supply is abnormally low or the circuit breaker is tripped. 410 SERVO ALARM: nTH AXIS EXCESS ERROR. Either RAM Parity or the power off signal occurs. 1) A G code that belongs to group 01 except G00 and G01 is specified in G41.3 mode. Fanuc 0i/0i Mate Fanuc 10/11/12 Fanuc Series 15 Fanuc 15i Fanuc 16i 18i Fanuc 21 Fanuc 21i Fanuc Alarms Fanuc Spindle Alarms Fanuc 6M 6T Alarms Fanuc Alarm 4063 RF POWER SUPPLY Fanuc laser alarm Description The RF power in the laser oscillator is under an abnormal condition. Lakeside CNC Group, Inc. is an independent repair lab situated in Bensenville, IL. Fill out the form below and a knowledgeable FANUC automation expert will be in touch. ;4) Tool center point control is provided during tool length compensation, or tool length compensation is applied during tool center point control. What Is CNC G Code? An axis not specified with controlled points is specified in the first block. A mode that cannot be used with NURBS interpolation mode is specified in NURBS interpolation mode. 3) series SVU: The control power supply voltage has dropped. 6 The control power supply voltage decreases. was set in parameter No. How to reset it? Common G Codes & Commands, FANUC CNC Troubleshooting Frequently Asked Questions, Low-Code and the Future of PLC Programming, MicroMaster 440 Parameter List and Fault Codes, Emerson Commander SK Advanced User Guide & Manual, The Most & Least Power Outages by U.S. State, Sinamics S120 Fault Codes and Alarms, Part I. We deliver culinary drinking water to almost 6,722 connections daily. FANUC alarm codes vary in specificity. Try again from the manual reference position return. Power Supply Alarm 10 or ASpindle Amplifier Alarm b3CNC Alarm SP9113Applies to Alpha i Power SupplyAlarm 10 or A on the Alpha i power supply indicates a fail. The position deviation value when the nth axis (axis 18) moves is larger than the set value. These procedures should include releasing all energies related to the maintenance procedure performed.How come Mr. FANUC video guy can't figure out if my power supply will have an A or a 10 on it? AL06: The Input Power Supply is abnormal (open phase). However, the different alarms identify which amplifier axis the alarm exists on. Fuse F7in DC link is blown out. Cause of alarm: Servo amplifier or common power supply voltage is too high. The input power supply is abnormal (open phase). Converter: control power supply undervoltage, Inverter: internal cooling fan stopped or circuit failed, Inverter: cooling fan stopped of the radiator, Excessive offset of the phase U current detection circuit, Excessive offset of the phase V current detection circuit, Position sensor polarity setting incorrect, Overcurrent in the converter input circuit, Parameter data out of the specifiable range, Position coder one-rotation signal detection error, Position coder one-rotation signal not detected, Excessive speed command calculation value during spindle synchronization, Motor sensor one-rotation signal detection error, Motor sensor one-rotation signal not detected, Spindle sensor one-rotation signal detection error, Spindle sensor one-rotation signal not detected, Converter: control power supply low voltage, Input power supply is abnormal (open phase), DC voltage at the DC link is abnormally high. Refer to procedure of trouble shooting. What you should expect to see is dashes on the servo amplifiers, a b3 on the spindle amplifier, and either an A or 10 on the power supply. . <1> If blinking continues Replace the Servo Amplifier. 3) series SVU: The C link voltage is too high. f (2)Cause and troubleshooting (a)The input power supply has an open phase. No knot is specified. A: A cooling fan of external cooling has stopped. Due to an NC or servo system fault in the reference position return, there is the possibility that reference position return could not be executed correctly. This error usually occurs as the result of an improperly set parameters. Fanuc power supply alarm on PSM modules from the group that has been repairing Fanuc ALPHA power supply modules for over 20 years. The power supply department should notify in advance before power outages in areas where there are frequent power outages.